BD Microtainer® blood collection tubes are designed for ease of use, helping ensure that a quality capillary blood sample is collected. These wider-diameter tubes feature the BD Microgard™ closure, which has an integrated collection scoop and improved mixing ability. This full array of microcollection tubes is available for hematology and chemistry applications, and is color coded to match the array of evacuated BD Vacutainer® blood collection tubes.

true
Caractéristiques et avantages
Notre Histoire
false
Spécification

GTIN - null

50382903659635

200

GTIN - null

30382903659631

50

GTIN - null

00382903659630

1


Quantité - Boîte

50

Quantité - Boîte

200


Couleur

Rouge

Additif/Concentration

Enduit de silicone

Volume de remplissage

250–500

GTIN

GTIN - null 50382903659635 200
GTIN - null 30382903659631 50
GTIN - null 00382903659630 1

Emballage

Quantité - Boîte 50
Quantité - Boîte 200

Spécifications du produit

Couleur Rouge
Additif/Concentration Enduit de silicone
Volume de remplissage 250–500
Ressources
Questions fréquentes

BD microcollection Tubes are packaged 50/bag, 200/case.

<p>According to CLSI "Procedures and Devices for the Collection of Diagnostic Capillary Blood Specimens" (H4-A6 Vol. 28 #25 September 2008) draw order should be:</p> <ol> <li>EDTA tubes</li> <li>Other additive tubes</li> <li>Serum tubes</li> </ol>

The caps are HDPE (high density polyethylene) and the tubes are polypropylene.

Microtainer tubes are equipped with two different closure types. The external dimensions of tubes with the BD Microgard™ closure are 15.35-mm X 46-mm. Microtainer tubes with FloTop collector closures meaure 9.85-mm X 52.07-mm.

Microtainer tubes with gel should be spun at 6000-15000 relative centrifugal force (RCF) for 90 seconds and non-gel tubes at a minimum of 2000 RCF for 3 minutes.

BD Microtainer K2EDTA with Microgard™ closure (#365974) is certified for lead. The background amount of lead is less than 1 ng per tube.

There is enough K2EDTA to anticoagulate blood volume from 250-500 μL. The average amount of K2EDTA in the tube is 1.0-mg.

Specimens can be stored in Microtainer® EDTA tubes for up to four hours at room temperature prior to performing hematological determinations

The BD Microtainer serum seperator tubes are available with two different closure types. The tube with BD Microgard™ closure (#365967) has clot activator on the walls. The tube with an attachable Flo-Top collector (#365956) does not have a clot activator on the walls.

BD microcollection Tubes are packaged 50/bag, 200/case.

<p>According to CLSI "Procedures and Devices for the Collection of Diagnostic Capillary Blood Specimens" (H4-A6 Vol. 28 #25 September 2008) draw order should be:</p> <ol> <li>EDTA tubes</li> <li>Other additive tubes</li> <li>Serum tubes</li> </ol>

The caps are HDPE (high density polyethylene) and the tubes are polypropylene.

Microtainer tubes are equipped with two different closure types. The external dimensions of tubes with the BD Microgard™ closure are 15.35-mm X 46-mm. Microtainer tubes with FloTop collector closures meaure 9.85-mm X 52.07-mm.

Microtainer tubes with gel should be spun at 6000-15000 relative centrifugal force (RCF) for 90 seconds and non-gel tubes at a minimum of 2000 RCF for 3 minutes.

BD Microtainer K2EDTA with Microgard™ closure (#365974) is certified for lead. The background amount of lead is less than 1 ng per tube.

There is enough K2EDTA to anticoagulate blood volume from 250-500 μL. The average amount of K2EDTA in the tube is 1.0-mg.

Specimens can be stored in Microtainer® EDTA tubes for up to four hours at room temperature prior to performing hematological determinations

The BD Microtainer serum seperator tubes are available with two different closure types. The tube with BD Microgard™ closure (#365967) has clot activator on the walls. The tube with an attachable Flo-Top collector (#365956) does not have a clot activator on the walls.

true
Produits connexes
Produits connexes non disponibles
Plaintes concernant un produit
North American Regional Complaint Center
1-844-8BD-LIFE (1-844-823-5433)
Élements à prendre en compte

Si vous êtes un patient ou un utilisateur final, vous pouvez nous contacter vous-même, ou vous pouvez demander à votre soignant ou à votre médecin de le faire pour vous. Pour nous aider à traiter vos
informations rapidement et efficacement, veuillez contacter notre équipe chargée des réclamations clients.

Pour faciliter notre enquête, veuillez inclure les informations suivantes dans votre rapport:


  • Nom du produit et/ou numéro de catalogue
  • Numéro de lot ou numéro de série
  • Blessures et/ou préjudices?
  • Quel est le problème que vous avez rencontré?
  • Est-ce-que l'échantillon réel ou le représentant de l'échantillon est disponible? (Si possible, veuillez envoyer l'échantillon concerné)
  • Nom et numéro de téléphone de la personne à contacter