{"AlternateComparison":false,"RelatedProducts":false,"Specification":true,"FeatureBenefit":false}
PowerPICC™ I.R. PICC catheters PowerPICC™ Provena™ Catheters

PowerPICC™ Provena™ 5 Fr Triple Lumen Catheter - Nursing Full Tray with Sherlock™ Tip Location System Stylet

Overview

Think big. Go small.

BD is committed to providing safe and effective vascular access solutions to advance lives and the delivery of health care. By combining advances in polyurethane-material technology and manufacturing processes, BD has developed smaller-diameter* peripherally inserted central catheters (PICCs) that maintain high flow performance for infusion therapy.

*Size comparison in relation to PowerPICC™ Catheters of the same lumen configuration.

true
Features and Benefits
Promotional Story
false
References
false
Specification

GTIN - Each

00801741112874

1

GTIN - Case

10801741112871

5


Gravity Flow Rate

824 mL/hr, 260 mL/hr

Lumen Gauge Size

18 Ga (Red), 19 Ga (Gray & White)

Maximum Achievable Pump Flow Rate

Saline (1.0 cP) > 999 mL/hr, TPN (2.0 cP) > 999 mL/hr, Blood (3.5 cP) = 649 mL/hr

Power Injection Flow Rate

5 mL/sec, N/A

Priming Volume

0.67 mL, 0.43 mL

GTIN

GTIN - Each 00801741112874 1
GTIN - Case 10801741112871 5

Product Basic Specification

Gravity Flow Rate 824 mL/hr, 260 mL/hr
Lumen Gauge Size 18 Ga (Red), 19 Ga (Gray & White)
Maximum Achievable Pump Flow Rate Saline (1.0 cP) > 999 mL/hr, TPN (2.0 cP) > 999 mL/hr, Blood (3.5 cP) = 649 mL/hr
Power Injection Flow Rate 5 mL/sec, N/A
Priming Volume 0.67 mL, 0.43 mL
References
false
Electronic Instructions for Use (eIFUs)
Resources
References
false
Frequently Asked Questions
false
References
false
Related Products
RELATED PRODUCTS NOT AVAILABLE
References
false
Product Complaints
North American Regional Complaint Center
1-844-8BD-LIFE (1-844-823-5433)
Things to Consider

If you are a patient or end user, you can contact us yourself, or you may have your caregiver or your physician do that for you. To help us process your
information quickly and effectively, please contact our customer complaints
team.

To better facilitate our investigation, please include the following information in your reporting:


  • Product Name and/or Catalog Number
  • Lot Number or Serial Number
  • Any injuries and/or Harm?
  • What is the issue you experienced?
  • Is the actual sample or sample representative available? (If possible, please send affected sample)
  • Contact name and phone number
Product Recalls
Literature Icon
Recall Notifications
These recall notices provide current information on medical device recalls.
Learn more
References
false
false