Specification

GTIN - Each

00382903868889

1

GTIN - Shelfpack

30382903868880

30

GTIN - Case

50382903868884

120


Quantity - Box

30

Quantity - Case

120


Blood Control

Yes

Catheter Gauge Size

16 G

Catheter Length

1.25 in.

Catheter Material

BD Vialon™

Catheter Inner Diameter (I.D.) Size

1.36 mm

Catheter Outer Diameter (O.D.) Size

1.74 mm

Hub Color

Gray

Gravity Flow Rate

190 mL/min (11,400 mL/hr)

High Pressure Rating

325 psi

Maximum power injector flow rate for contrast media viscosity ≤ 11.8 cP (mPa-s)

27.0 mL/sec

Maximum power injector flow rate for contrast media viscosity ≤ 27.5 cP (mPa-s)

18.0 mL/sec

Safety Engineered Feature

Passive

Sterilization Method

EtO

GTIN

GTIN - Each 00382903868889 1
GTIN - Shelfpack 30382903868880 30
GTIN - Case 50382903868884 120

Packaging

Quantity - Box 30
Quantity - Case 120

Product Basic Specification

Blood Control Yes
Catheter Gauge Size 16 G
Catheter Length 1.25 in.
Catheter Material BD Vialon™
Catheter Inner Diameter (I.D.) Size 1.36 mm
Catheter Outer Diameter (O.D.) Size 1.74 mm
Hub Color Gray
Gravity Flow Rate 190 mL/min (11,400 mL/hr)
High Pressure Rating 325 psi
Maximum power injector flow rate for contrast media viscosity ≤ 11.8 cP (mPa-s) 27.0 mL/sec
Maximum power injector flow rate for contrast media viscosity ≤ 27.5 cP (mPa-s) 18.0 mL/sec
Safety Engineered Feature Passive
Sterilization Method EtO
References
false
Electronic Instructions for Use (eIFUs)
Resources
References
false
Frequently Asked Questions
false
References
false
Related Products
RELATED PRODUCTS NOT AVAILABLE
References
false
Product Complaints
North American Regional Complaint Center
1-844-8BD-LIFE (1-844-823-5433)
Things to Consider

If you are a patient or end user, you can contact us yourself, or you may have your caregiver or your physician do that for you. To help us process your
information quickly and effectively, please contact our customer complaints
team.

To better facilitate our investigation, please include the following information in your reporting:


  • Product Name and/or Catalog Number
  • Lot Number or Serial Number
  • Any injuries and/or Harm?
  • What is the issue you experienced?
  • Is the actual sample or sample representative available? (If possible, please send affected sample)
  • Contact name and phone number
Product Recalls
Literature Icon
Recall Notifications
These recall notices provide current information on medical device recalls.
Learn more
References
false