Ultrascore™ Focused Force PTA balloon

Specialty Scoring Balloon

Contact Us
4l30qzdcgtsfv35htmjbmfncq34hczcj.jpg
Loading
Overview

Specialty scoring balloon technology

  • Specialty Scoring Balloon
  • Focused Force Dilatation
  • Low Profile, Over-the-Wire Design
  • 2 Longitudinal .010″ wires placed 180 degrees apart
  • .014″ & .035″ Compatible
  • Broadest Scoring Balloon Portfolio (up to 300mm)2
  • GeoAlign™ Marking System

The UltraScore™ Balloon is the first commercially available .035” scoring balloon, with sizes available on both .014” and .035” guidewire platforms.

true
Features and Benefits
Designed for Controlled Plaque Modification

Compared to a standard PTA balloon of the same size, UltraScore™ Focused Force PTA Balloon:

  • Provides approximately 24 times more force where the wire contracts the lesion2
  • Is designed to longitudinally fracture plaque at lower inflation pressure
  • May allow for more controlled plaque fracture and less vessel recoil, even in calcified lesions
Low Profile, Over-The-Wire Design

UltraScore™ Focused Force PTA Balloon is available on a 0.014" and 0.035" guidewire platform, and is the lowest profile scoring balloon on the U.S. market.1

  • Sheath profiles ranging from 4F - 6F
  • Only 0.035″ scoring balloon commercially available on the U.S. market1
  • Hydrophilic coating for optimized deliverability on 0.014” guidewire platform
GeoAlign™ Marking System

The UltraScore™ Focused Force PTA Balloon is the only scoring balloon to feature the GeoAlign™ Marking System

  • Standardized, non-radiopaque ruler on the catheter shaft is designed to facilitate repeat catheter and geographic alignment3
Products & Accessories
Sort by:
EIFUs
Resources
Reference

As of July 2024.
Based on theoretical calculation using equation P=F/A comparing UltraScore™ Balloon to POBA. Data on File, Bard Peripheral Vascular, Inc., Tempe, AZ. May not be predictive of clinical performance. Different tests may yield different results.
The GeoAlign™ Marking System provides an approximation that may not be an exact representation of the actual distance traveled intravascularly and should be confirmed under fluoroscopy. The GeoAlign™ Marking System is not a replacement for fluoroscopy. When the catheter is exposed to the vascular system, the location of the balloon should be confirmed while under high quality fluoroscopic observation. Animal data on file at Becton, Dickinson and Company, Tempe, AZ. Animal test results may not be indicative of clinical performance. Different test methods may yield different results. 

Please consult Instructions for Use under Resources for product indications for use, contraindications, warnings, precautions, complications, adverse events and detailed safety information.

true