true
Icon to close the modal
Support
Turkey
Phone Icon
+90 216 680 10 02
Fax Icon
+90 216 680 16 55
CC_Turkey@bd.com
Modal Close Icon
Icon to close thank you modal
Thank you for contacting our sales team!
A sales representive will get in touch with you shortly.
Middle East & North Africa
Phone Icon
+971 4 5592555
Fax Icon
+971 4 5592599
info_uae@bd.com
Saudi Arabia
Phone Icon
+966 11 472 7933
Fax Icon
+966 11 472 3387
Saudi_info@bd.com
Egypt
Becton Dickinson BV, Scientific Office Mivida Business Park, Building A2, 1st Floor, Office 107, New Cairo, Cairo, Egypt.

Aspirex™ Mechanical Aspiration Thrombectomy System 

Contact Us
Catheters
Loading
Overview
3-in-1 Thrombectomy

Aspiration + Maceration + Transportation


The AspirexTM Mechanical Aspiration Thrombectomy System offers a 3-in-1 mechanism of action designed to aspirate, macerate, and transport clot out of the vessel. 

true

Dynamic 3-in-1 Mechanism of Action

ADVANCED ASPIRATION

Internal helix rotates at 40,000 – 60,000 RPMs creating powerful suction at the catheter tip, aspirating clot through wall-apposed side windows

CONTINUOUS MACERATION

Clot is macerated by the internal helix as it enters the catheter, and is continuously macerated as it travels through the catheter to help mitigate clogging

MECHANICAL TRANSPORATION

Internal helix helps transport clot through the catheter, out of the vessel

Drive System

Small Footprint & Simple Set-Up

  • No Warm-up or repeated catheter clean-out required
  • Plug-and-play capital component

Drive System

    Case Example

    Recanalization of an Acute Iliofemoral Deep Vein Thrombosis Using the Aspirex™ 10F Catheter

    Dr Michael Lichtenberg, Chief Medical Officer, Karolinen Hospital, Arnsberg, Germany

    Venogram demonstrated complete thrombotic occlusion of the left iliac vein (figure 1). Mechanical Thrombectomy was performed with the 10F Aspirex™ Catheter (figure 2). At the 3 months clinical follow-up the patient presented symptom-free. Venous outflow was shown to be patent on the treated side.

    EIFUs
    Resources

    References

    *6F/8F catheters offer a single multi-sided L-shape window, 10F catheter offers two side windows.

    The Aspirex™ Mechanical Aspiration Thrombectomy System is indicated for the removal of acute emboli and thrombi from vessels in the peripheral venous system.

    The Aspirex™ Mechanical Aspiration Thrombectomy System is not for use in the vessels of the cardiac, pulmonary, coronary and neurovasculature. Please consult product labels and instructions for use for indications, contraindications, hazards, warnings, and precautions.

    BD-56967

    true