Simple. Safe. Effective.

Arista™ AH is a 100% plant based absorbable surgical hemostatic powder derived from purified plant starch. The power of Arista™ AH lies in its Microporous Polysaccharide Hemospheres, a patented blood clotting technology.

Arista™ AH is indicated in surgical procedures (except neurologic and ophthalmic) as an adjunctive hemostatic device to assist when control of capillary, venous, and arteriolar bleeding by pressure, ligature, and other conventional procedures are ineffective or impractical.

true
Features and Benefits
Promotional Story
false
Specification

GTIN - Each

00801741044137

1

GTIN - Case

10801741044134

5


Quantity

5/cs.


Dimensions

ARISTA™ AH 5 g

GTIN

GTIN - Each 00801741044137 1
GTIN - Case 10801741044134 5

Packaging

Quantity 5/cs.

Product Basic Specification

Dimensions ARISTA™ AH 5 g
Electronic Instructions for Use (eIFUs)
Resources
Frequently Asked Questions

Arista™ AH 흡수성 지혈 입자의 기본 사항

  • 국소 지혈제에는 출혈에 대한 기계적 분리 장벽 역할을 하고 응고를 위한 물리적 기질을 제공하는 제제와 응고를 촉진하는 생물학적 활성 제제, 그리고 복합 치료가 있습니다.2
  • 지혈제는 혈전 형성 및 상처 치유를 촉진할 수 있으며, 기존의 지혈 방법이 부적합한 수술을 하는 동안 번거로운 출혈을 제어하거나 예방하는 데 유용할 수 있습니다.2
  • AH는 출혈을 제어하기 위해 수술 부위에 사용하도록 고안된 흡수성 분말 지혈제입니다. 일반적으로 24~48시간 이내에 흡수되는 생체 적합적 비발열성 미세 건조 멸균 흰색 분말입니다."

 

  • Arista™ AH는 정제된 식물의 전분에서 유래한 100% 식물성 흡수성 수술용 지혈 분말입니다. Arista™ AH의 힘은 특허 받은 혈액 응고 기술인 미소공성 다당류 헤모스피어에 있습니다. 제어된 기공 크기의 미소공성 입자로 구성된 구체는 분자체로 작용하도록 설계되었습니다. 강력한 삼투 작용은 접촉한 혈액을 건조하고 젤화하여 자연적인 응고 과정을 가속화합니다."

Arista™ AH 작용 및 사용 방법

  • 'RAPID'라는 약자를 사용해 사용 단계를 기억할 수 있습니다.
  • R(제거):잉여 혈액을 모두 제거합니다
  • A(도포):출혈 부위에 AristaTM AH를 넉넉하게 도포합니다
  • P(압력): 지혈이 이루어질 때까지 상처에 적절한 압력을 가합니다
  • I(세척): 상처 부위에서 남은 Arista™ AH를 세척하고 제거합니다
  • D(완료): 지혈을 통해 신속하고 안전하며 효과적으로 지혈할 수 있습니다
 
  • FlexiTip™ 스프레이 어플리케이터를 사용하면 Arista™ AH를 정확하고 직접적으로 도포하는 것이 빠르고 간단합니다. 전달 시스템은 길고 유연한 튜브가 있는 경량의 플라스틱 기구가 특징입니다. FlexiTip™ 및 FlexiTip™ XL 확장 어플리케이터 팁은 간단한 일회용 기구로 Arista™ AH 지혈 분말을 정확하고 정확하게 전달합니다.1
  • Arista 도포: 사용 지침 참조 1
 
  • 사용 방법:
  1. 출혈 조직을 덮거나 문질러서 닦아내거나 빨아들입니다. 잉여 혈액을 제거하여 Arista™ AH를 출혈 부위에 즉시 바로 사용할 수 있도록 하는 것이 중요합니다.
  2. 어플리케이터 팁을 출혈원에 최대한 가깝게 배치합니다. 상처 내 출혈 부위에 넉넉한 양의 Arista™ AH를 즉시 적용하여 상처를 완전히 덮습니다. 깊은 상처는 Arista™ AH를 똑같이 깊게 적용해야 할 수 있습니다. 팁이 막히는 것을 최소화하기 위해 어플리케이터를 상처에 넣을 때 압력을 가해 Arista™ AH를 전달해야 합니다.
  3. 상처에 적합한 수준으로 치료 부위에 직접적인 압박을 신속히 가합니다. 비접착성 기질을 사용하여 압박을 가하면 혈전이 수술 장갑이나 다른 기구에 들러붙는 것을 방지할 수 있습니다. 압박의 크기와 지속시간은 상처에 따라 다릅니다. 삼출성인 경우 압박이 필요하지 않을 수도 있습니다. 다량 출혈 상처에는 압박을 더 오랫동안 유지해야 합니다.
  4. 출혈이나 삼출이 계속되면 잉여 Arista™ AH를 제거하고 다시 도포합니다.
  5. 혈전에 결합된 Arista™ AH가 아닌 다른 물질(예: 수술 드레싱)이 상처 부위에 붙으면 식염수로 물질을 세척하고 치료 부위에서 조심스럽게 제거합니다.
  6. Arista™ AH는 혈액 또는 액체에 닿는 즉시 원래 부피의 약 5배까지 팽창합니다. 지혈이 이루어지면 잉여 Arista™ AH를 세척하거나 흡인해서 조심스럽게 제거해야 합니다. 형성된 혈전을 직접 흡인하거나 세척하지 마십시오.1
  • 투여: 출혈 부위에 넉넉한 양의 Arista™ AH를 도포하고(사용 지침 참조) 지혈이 이루어질 때까지 압력을 가해야 합니다.지혈이 이루어지면 Arista™ AH를 세척 및/또는 흡인해서 제거해야 합니다.1

Arista™ AH가 사용될 수 있는 수술의 예는 다음과 같습니다.

  • 심흉부 및 심혈관
  • 혈관
  • 부인과
  • 비뇨기과
  • 정형외과 수술
  • 일반외과 수술
  • 성형외과 수술
  • 인후부(ENT) 수술

Arista™ AH의 장점

  • 다양한 국소 지혈제는 일반적인 방법이 불충분하거나 실용적이지 않은 수술 절차 동안 지혈 유지를 위한 보조 요법으로 승인되었습니다.2
  • 외과적 출혈을 관리하기 위한 병원 자원의 추가 활용을 방지하는 측면에서 잠재적인 비용 이점이 있습니다. 기타 환자 혈액 관리 전략 이외에도, 국소 지혈제의 수술 중 사용은 상당한 비용이 수반되는 혈액 제제(예: 농축 적혈구, 혈소판, 신선한 냉동 혈장)의 수혈 필요를 줄이고 수술 후 관리 기간(병원 입원 기간)을 줄일 수 있습니다.2

간단한 사용법

  • 즉시 사용 가능
  • 캡을 열고 분말을 출혈 부위에 바로 적용하기만 하면 됨
  • 혼합 및 냉장 보관 불필요
  • 유효 기간 5년4

안전하며 트롬빈 불포함

  • 정제된 식물 전분 합성
  • 트롬빈 불포함, 생체 적합적이며 비발열성
  • 일반적으로 아밀라아제로 24~48시간 이내 흡수 및 제거
  • Arista™ AH는 혈구 회수 호환성을 위해 승인된 현재 이용 가능한 유일한 지혈제임1,6,7

효과적인 지혈제

  • 환자의 응고 상태에 관계 없이 접촉 시 응고 과정 시작
  • 몇 분 내로 완전한 지혈 가능5
  • 넓은 적용 범위 제공

Arista™ AH 결과 및 사례 연구

PMA 임상 시험(일반외과, 정형외과, 심장)

심장 및 혈관:

이비인후과:

일반외과:

비뇨기과

참고 자료

 

  1. Arista™ AH 사용 지침
  2. Gabay, M. & Boucher, B.A. An essential primer for understanding the role of topical hemostats, surgical sealants, and adhesives for maintaining hemostasis. Pharmacotherapy 33, 935-955 (2013).
  3. ARISTA™ AH의 안전성과 유효성은 어린이와 임산부를 대상으로 임상적으로 평가되지 않았습니다. 신생아부터 생후 10개월까지 아밀라아제 활성도가 감소되었다는 보고가 있었기 때문에 이 모집단에서 ARISTA™ AH의 흡수율은 48시간 이상일 수 있습니다.
  4. 파일 데이터
  5. ARISTA™ AH PMA 임상 연구 P050038
  6. BD 파일 데이터. 전임상 데이터는 인간에 대한 임상 성능과 상관관계가 없을 수도 있습니다.
  7. Arista™ AH를 자가 혈액 회수 회로와 함께 사용할 경우 40μ의 심장 절개 저장고, 세포 세척, 40μ의 수혈 필터를 사용해야 합니다.

BD-53859

true
Alternatives Comparison
  • Alternatives Comparison

    • Product Name
    • SKU Number
    • Dimensions
    • Quantity
    • Product Name
    • SKU Number
    • Dimensions
    • Quantity
    • Product Name
    • SKU Number
    • Dimensions
    • Quantity
    • Product Name
    • SKU Number
    • Dimensions
    • Quantity
    • Product Name
    • SKU Number
    • Dimensions
    • Quantity
  • Product Image
    • Product Name

      Arista™ AH 5g
    • SKU Number

      sm0007
    • Dimensions

      ARISTA™ AH 5 g
    • Quantity

      5/cs.
  • Product Image
    • Product Name

      Arista™ AH 3g
    • SKU Number

      sm0002
    • Dimensions

      ARISTA™ AH 3 g
    • Quantity

      5/cs.
  • Product Image
    • Product Name

      Arista™ AH 1g
    • SKU Number

      sm0005
    • Dimensions

      ARISTA™ AH 1 g
    • Quantity

      5/cs.
Related Products
RELATED PRODUCTS NOT AVAILABLE
References

1 Arista™ AH PMA P050038 Clinical Study.

2 See full Instructions for Use for detailed application instructions.

3 Arista™ AH Instructions for Use.

INDICATIONS

Arista™ AH is indicated in surgical procedures (except neurological and ophthalmic) as an adjunctive hemostatic device to assist when control of capillary, venous, and arteriolar bleeding by pressure, ligature, and other conventional procedures are ineffective or impractical.

CONTRAINDICATIONS

Do not inject or place Arista™ AH into blood vessels as potential for embolization and death may exist.

WARNINGS

Arista™ AH is not intended as a substitute for meticulous surgical technique and the proper application of ligatures or other conventional procedures for hemostasis.

Once hemostasis is achieved, excess Arista™ AH should be removed from the site of application by irrigation and aspiration particularly when used in and around foramina of bone, areas of bony confine, the spinal cord, and/or the optic nerve and chiasm. Arista™ AH swells to its maximum volume immediately upon contact with blood or other fluids. Dry, white Arista™ AH should be removed. The possibility of the product interfering with normal function and/or causing compression necrosis of surrounding tissues due to swelling is reduced by removal of excess dry material.

Safety and effectiveness of Arista™ AH have not been clinically evaluated in children and pregnant women. Because there have been reports of decreased amylase activity in newborns up to 10 months, absorption rates of Arista™ AH in this population may be longer than 48 hours.

Arista™ AH should be used with caution in the presence of infection or in contaminated areas of the body. If signs of infection or abscess develop where Arista™ AH has been applied, re-operation may be necessary in order to allow drainage.

Safety and effectiveness in neurosurgical and ophthalmic procedures has not been established.

Arista™ AH should not be used for controlling post-partum bleeding or menorrhagia.

PRECAUTIONS

When Arista™ AH is used in conjunction with autologous blood salvage circuits, carefully follow instructions in the Administration section of the IFU regarding proper filtration and cell washing.

Arista™ AH is intended to be used in a dry state. Contact with saline or antibiotic solutions prior to achieving hemostasis will result in loss of hemostatic potential.

Arista™ AH is not recommended for the primary treatment of coagulation disorders.

No testing has been performed on the use of Arista™ AH on bone surfaces to which prosthetic materials are to be attached with adhesives and is therefore not recommended.

Arista™ AH is supplied as a sterile product and cannot be resterilized. Unused, open containers of Arista™ AH should be discarded.

Do not apply more than 50g of Arista™ AH in diabetic patients as it has been calculated that amounts in excess of 50g could affect the glucose load.

In urological procedures, Arista™ AH should not be left in the renal pelvis or ureters to eliminate the potential foci for calculus formation.

ADVERSE REACTIONS

None of the adverse events that occurred in a randomized prospective, concurrently controlled clinical trial were judged by the Data Safety Monitoring Board to be related to the use of Arista™ AH. The most common recorded adverse events were pain related to surgery, anemia, nausea, lab values out of normal range, arrhythmia, constipation, respiratory dysfunction and hypotension – all reported in greater than 10% of the Arista™ AH treated patients. The details of this clinical trial’s adverse events can be reviewed in the IFU supplied with the product and are also available at www.bd.com.

Caution: Federal (USA) law restricts this device to sale by or on order of a licensed physician or properly licensed practitioner.