BD Vacutainer® Trace Element Serum Plus Blood Collection Tubes

Icon to close the modal
지원
Becton, Dickinson and Company
전화 아이콘
(82.2) 080-340-3800
bd_korea@bd.com
모달 닫기 아이콘
감사 모달 닫기 아이콘
영업팀에 연락해 주셔서 감사합니다!
영업 담당자가 곧 연락을 드립니다.
Address
위치 아이콘
Becton Dickinson Korea Co., Ltd. 한국 서울특별시 강남구 테헤란로 142 아크플레이스 16층 06236
Overview

BD는 BD Vacutainer® 채혈 튜브의 글로벌 제조사입니다. 저희는 고객이 최적의 결과를 얻을 수 있도록 광범위한 임상 전문 지식과 교육 자료를 통해 제품을 지원합니다.

true
Features and Benefits
Promotional Story
false
Specification

GTIN - Each

00382903683802

1

GTIN - Case

50382903683807

1000

GTIN - Shelfpack

30382903683803

100


Quantity - Box

100

Quantity - Case

1000

GTIN

GTIN - Each 00382903683802 1
GTIN - Case 50382903683807 1000
GTIN - Shelfpack 30382903683803 100

Packaging

Quantity - Box 100
Quantity - Case 1000
Electronic Instructions for Use (eIFUs)
Resources
Frequently Asked Questions

BD Vacutainer Plus Tubes are made of a special formulation of the plastic, polyethylene terephthalate (PET). This special formulation is extremely strong, dimensionally stable, and resistant to chemicals and breakage.

All non-gel separator blood collection tubes, including those that contain heparin, EDTA and non-gel serum tubes can be centrifuged at ≤1300 RCF for 10 minutes. The BD Vacutainer SST and PST gel tubes should be spun at room temperature at a speed of 1000 to 1300 RCF for 10 minutes in a swinging bucket centrifuge and 15 minutes in a fixed-angle centrifuge. The BD Vacutainer Barricor plasma blood collection tubes have a mechanical separator and must be spun at a minimum RCF of 1800 for 10 min in a swinging bucket centrifuge. BD Barricor tubes are optimally spun at an RCF of 4000 for 3 min in a swinging bucket centrifuge. BD Barricor tubes are not compatible with fixed angle centrifuges.

BD Vacutainer Plus plastic serum and SST tubes are coated with silicone and micronized silica particles to accelerate clotting. A silicone coating reduces adherence of red cells to tube walls. The silica coating can sometimes cause the inner tube wall to appear cloudy and/or filmy. This cloudy appearance does not make the tubes unacceptable for use.

Most BD Vacutainer blood collection tubes are packaged 100 tubes/box and 1,000 tubes/case (10 boxes).

No, BD does not claim that any of the Vacutainer blood collection tubes are endotoxin free.

The expiration date on the tube label is stated as a Year/Month/Day.

Local trash collectors should be consulted to see what the proper method of disposal is for unused, expired blood collection products.

Yes, BD Vacutainer blood collection tubes have a sterile interior. Tubes are sterilized by gamma radiation.

BD Vacutainer tubes are irradiated to achieve sterility. These tubes are sterile on the interior only. We cannot recommend re-sterilizing the tubes, i.e., ETO (ethylene oxide) or autoclaving, primarily due to pressure changes that take place during the re-sterilization cycle. Our tubes are under a specific negative pressure. During the re-sterilization cycle this negative pressure may be disrupted and therefore the tubes may not draw the proper blood volume.

BD does offer a sterile peel-apart pouch (reference number 366401) that contains a 10 mL glass red top serum tube and 7 mL glass lavender top EDTA tube.

BD Vacutainer Plus Tubes are made of a special formulation of the plastic, polyethylene terephthalate (PET). This special formulation is extremely strong, dimensionally stable, and resistant to chemicals and breakage.

All non-gel separator blood collection tubes, including those that contain heparin, EDTA and non-gel serum tubes can be centrifuged at ≤1300 RCF for 10 minutes. The BD Vacutainer SST and PST gel tubes should be spun at room temperature at a speed of 1000 to 1300 RCF for 10 minutes in a swinging bucket centrifuge and 15 minutes in a fixed-angle centrifuge. The BD Vacutainer Barricor plasma blood collection tubes have a mechanical separator and must be spun at a minimum RCF of 1800 for 10 min in a swinging bucket centrifuge. BD Barricor tubes are optimally spun at an RCF of 4000 for 3 min in a swinging bucket centrifuge. BD Barricor tubes are not compatible with fixed angle centrifuges.

BD Vacutainer Plus plastic serum and SST tubes are coated with silicone and micronized silica particles to accelerate clotting. A silicone coating reduces adherence of red cells to tube walls. The silica coating can sometimes cause the inner tube wall to appear cloudy and/or filmy. This cloudy appearance does not make the tubes unacceptable for use.

Most BD Vacutainer blood collection tubes are packaged 100 tubes/box and 1,000 tubes/case (10 boxes).

No, BD does not claim that any of the Vacutainer blood collection tubes are endotoxin free.

The expiration date on the tube label is stated as a Year/Month/Day.

Local trash collectors should be consulted to see what the proper method of disposal is for unused, expired blood collection products.

Yes, BD Vacutainer blood collection tubes have a sterile interior. Tubes are sterilized by gamma radiation.

BD Vacutainer tubes are irradiated to achieve sterility. These tubes are sterile on the interior only. We cannot recommend re-sterilizing the tubes, i.e., ETO (ethylene oxide) or autoclaving, primarily due to pressure changes that take place during the re-sterilization cycle. Our tubes are under a specific negative pressure. During the re-sterilization cycle this negative pressure may be disrupted and therefore the tubes may not draw the proper blood volume.

BD does offer a sterile peel-apart pouch (reference number 366401) that contains a 10 mL glass red top serum tube and 7 mL glass lavender top EDTA tube.