{"AlternateComparison":false,"RelatedProducts":false,"Specification":true,"FeatureBenefit":false}
CapSure™ CapSure™ Permanent Fixation System

CapSure™ Permanent Fixation System - 30 Permanent Fasteners

Icon to close the modal
지원
Becton, Dickinson and Company
전화 아이콘
(82.2) 080-340-3800
bd_korea@bd.com
모달 닫기 아이콘
감사 모달 닫기 아이콘
영업팀에 연락해 주셔서 감사합니다!
영업 담당자가 곧 연락을 드립니다.
Address
위치 아이콘
Becton Dickinson Korea Co., Ltd. 한국 서울특별시 강남구 테헤란로 142 아크플레이스 16층 06236
Overview
영구 고정 재정의

CapSure™는 강력하고 안정적인 고정을 통해 외과의가 원하는 자신감을 제공합니다.

true
Features and Benefits
Promotional Story
false
Specification

GTIN - Each

00801741094996

1

GTIN - Case

10801741094993

5


Quantity

5/cs


Dimensions

CapSure™ Permanent Fixation System - 30 Fasteners

GTIN

GTIN - Each 00801741094996 1
GTIN - Case 10801741094993 5

Packaging

Quantity 5/cs

Product Basic Specification

Dimensions CapSure™ Permanent Fixation System - 30 Fasteners
Electronic Instructions for Use (eIFUs)
Resources
Frequently Asked Questions
false
Related Products
RELATED PRODUCTS NOT AVAILABLE
References

1. Bench top data. Results many not correlate to performance in humans.

2 Preclinical data. Results may not correlate to performance in humans

Indications

The CapSure™ Permanent Fixation System is indicated for the approximation of soft tissue and fixation of surgical mesh to tissues during open or laparoscopic surgical procedures, such as hernia repair.

Contraindications

Carefully inspect the area in the vicinity of the tissue being fastened to avoid inadvertent penetration of underlying structures such as bone, nerves, vessels, and viscera. Use of the CapSure™ Permanent Fixation System in the close vicinity of such underlying structures is contraindicated. For reference, the length of the fastener below the fastener head is 3.2 mm, the fastener head is another 1 mm (total 4.2 mm).

Precautions

Adequate counter pressure should be applied on the target area. Avoid placing hand or finger directly over the area where fastener is being deployed to prevent injury. Use caution when applying the CapSure™ fastener over or in proximity to underlying bone, vessels, nerves, or viscera. The intended fixation site should be assessed to ensure that while the tissue is compressed the total distance from the surface of the tissue to any underlying structures is greater than the length of the CapSure™ fastener.

Adverse Reactions

Adverse reactions and potential complications associated with fixation devices such as the CapSure™ Permanent Fixation System may include, but are not limited to the following: hemorrhage, pain, edema and erythema at wound site; septicemia/infection; hernia recurrence/wound dehiscence, erosion and allergic response in patients with known sensitivities to PEEK and metals contained in 316L stainless steel, including chromium, nickel, copper, and iron.

true
true