Aspirex™ Mechanical Aspiration Thrombectomy System 

Contact Us
Catheters
Loading
Overview
Icon to close the modal
Support
Becton, Dickinson and Company
Phone Icon
0124-4124300
bd_india@bd.com
Modal Close Icon
Contact Us

 

 

Icon to close thank you modal
Thank you for contacting our sales team!
A sales representive will get in touch with you shortly.
Address
Location Icon
6th Floor Signature Tower - B, South City I, NH 8 Gurgaon, 122001, Haryana
true

*6F and 8F catheters are the only sizes indicated for arteriovenous fistulas and arteriovenous grafts.

Dynamic 3-in-1 Mechanism of Action

ADVANCED ASPIRATION

Internal helix rotates at 40,000 – 60,000 RPMs creating powerful suction at the catheter tip, aspirating clot through wall-apposed side windows

CONTINUOUS MACERATION

Clot is macerated by the internal helix as it enters the catheter, and is continuously macerated as it travels through the catheter to help mitigate clogging

MECHANICAL TRANSPORATION

Internal helix helps transport clot through the catheter, out of the vessel

Drive System

Small Footprint & Simple Set-Up

  • No Warm-up or repeated catheter clean-out required
  • Plug-and-play capital component

Drive System

    Case Example

    Recanalization of an Acute Iliofemoral Deep Vein Thrombosis Using the Aspirex™ 10F Catheter

    Dr Michael Lichtenburg, Chief Medical Officer, Karolinen Hospital, Arnsberg, Germany

    Venogram demonstrated complete thrombotic occlusion of the left iliac vein (figure 1). Mechanical Thrombectomy was performed with the 10F Aspirex™ Catheter (figure 2). At the 3 months clinical follow-up the patient presented symptom-free. Venous outflow was shown to be patent on the treated side.

    This clinical experience is presented or informational purposes only. The results from this case study may not be predictive for all patients. Individual results may vary depending on a variety of patient specific attributes.

    Products & Accessories
    RELATED PRODUCTS NOT AVAILABLE
    EIFUs
    Icon to close the modal
    Support
    Becton, Dickinson and Company
    Phone Icon
    0124-4124300
    bd_india@bd.com
    Modal Close Icon
    Contact Us

     

     

    Icon to close thank you modal
    Thank you for contacting our sales team!
    A sales representive will get in touch with you shortly.
    Address
    Location Icon
    6th Floor Signature Tower - B, South City I, NH 8 Gurgaon, 122001, Haryana
    true
    Resources

    References

    **6F/8F catheters offer a single multi-sided L-shape window, 10F catheter offers two side windows.

    The Aspirex™ Thrombectomy System is indicated for the removal of acute emboli and thrombi from vessels of the peripheral venous system. The 6F and 8F Aspirex™ Thrombectomy Catheters are indicated for the removal of acute emboli and thrombi from hemodialysis access grafts and native arteriovenous fistulas.

    The Aspirex™ Mechanical Aspiration Thrombectomy System is not for use in the vessels of the cardiac, pulmonary, coronary and neurovasculature. Please consult product labels and instructions for use for indications, contraindications, hazards, warnings, and precautions.

    BD-56967v2