- Dual lumen
- Kink-resistant catheter design
- Symmetrical tip
- Catheter length options
- Maximal barrier trays
- Straight or curved extension legs
13 French DuoGlide® Short-Term Dual Lumen Catheters are available in a variety of lengths including a long 30 cm length for femoral placements. Catheters are available in two configurations – with straight and curved extension legs – and in standard kits and maximal barrier precautions trays available for order in conjunction with the standard kits. Maximal barrier precautions trays help clinicians comply with CPSI, HC, and CCOHS guidelines and feature a full body drape (70” x 110”), a surgical gown, and safety components.
Optimal Performance Features2
Benefits of the DuoGlide™ Short-Term Dual Lumen Dialysis Catheters
Feature a full body drape (70" x 110"), surgical gown, and safety components.
Maximal barrier precautions help you comply with the latest guidelines from:
BD supports the healthcare industry with market-leading products and services that aim to improve care while lowering costs. We host and take part in events that excel in advancing the world of health™.
Description | Kit |
---|---|
DuoGlide™ Short-Term Dual Lumen Dialysis Catheter | 1 |
Attachable Suture Wing | 1 |
Transparent dressing | 1 |
Dualator™ Vessel Dilator 11-13 Fr | 1 |
Dualator™ Vessel Dilator 12-14 Fr | 1 |
End Cap | 2 |
StruXure™ Guidewire J-tip 70 cm x 0.89 mm (0.035 in.) | 1 |
Introducer Needle, 18 Ga. x 7 cm (2.75 in.) | 1 |
The DuoGlide Catheters are indicated for use in attaining short-term (less than 30 days) vascular access for hemodialysis, hemoperfusion, and apheresis therapy via the jugular, subclavian or femoral vein.
The catheter is intended for short-term vascular access only and is not to be used for any purpose other than indicated.
The DuoGlide Catheter flows at 400 mL/min for all lengths with low arterial/venous pressures (less than 250 mmHg). As suggested by in vitro data using a blood simulate approximating the viscosity of whole blood.
The rate of recirculation of the dialysis lumens is less than 1% on average in both the forward and reverse directions when tested in vitro1 at a flow rate of 300 mL/min with the symmetrical tip design of the 24 cm DuoGlide Short Term Dialysis Catheter. Note that recirculation in femoral catheters is likely significantly greater than in internal jugular placed catheters.2
Bench test results may not necessarily be indicative of clinical performance.
The DuoGlide Catheter outer diameter is 13 French. The intra lumens are large 12 gauge lumens that allow for flows of 400 mL/min.
The DuoGlide Catheter is available in both straight and curved extension leg configurations.
The DuoGlide Catheter is available in 12.5 cm (curved extension configuration only), 15 cm, 20 cm, 24 cm, and 30 cm (straight extension configuration only).
Transparent, rotatable wing allows for easy visualization and cleaning of exit site.
The DuoGlide Catheter is available in standard kit configurations only. Full maximal barrier precautions trays are available for order in conjunction with the standard kits and are compliant with Health HC, CPSI, and CCOHS guidelines.
The DuoGlide Catheter is intended to be inserted in the jugular, femoral, or subclavian vein as required.
WARNING: The catheter must not be left in the femoral vein longer than three days.
The DuoGlide Dialysis Catheter is compatible with the following agents: Povidone iodine, 0.55% sodium hypochlorite solution, chlorhexidine gluconate 4%, chlorhexidine gluconate 2% solution, dilute aqueous sodium hypochlorite, hydrogen peroxide, bacitracin zinc ointments in petrolatum bases.
WARNING: Acetone and PEG-containing ointments can cause failure of this device and should not be used with polyurethane catheters. Chlorhexidine patches or bacitracin zinc ointments are the preferred alternatives.
Yes. The StatLock Catheter Stabilization Device is compatible and can be ordered separately from the Bard Medical Division at 800-526-4455. The part number is DI0122.
Yes, the DuoGlide Catheter may be exchanged over a guidewire. The wire included in the kit is a 0.035 inch wire which fits through the venous lumen of the catheter.
Available sizes: 13 Fr.
Please consult product labels, IFU, and package inserts for any indications, contraindications, hazards, warnings, cautions, and instructions for use.
BD-19967 (03/23)